Ridge vent along the peak of a San Antonio asphalt shingle roof, on a home where the attic ventilation had been installed incorrectly.
Attic performance

Attic ventilation in San Antonio, calculated instead of guessed.

Soffit intake and ridge exhaust sized from your attic's floor area, so the attic stays dry on winter nights and sheds heat in summer.

We call back within minutes, any hour. No obligation.
Quick answer

Balanced attic ventilation means cool air comes in at the soffits and warm, moist air leaves at the ridge, with roughly equal net free area on each side. The amount is sized from the attic floor area, not guessed from how many vents are on the roof. We calculate it on every inspection, even when the attic looks fine, because buried intake and mismatched exhaust are hard to see from the hatch.

Work out your own attic with the ventilation calculator

Why it matters in winter, not just summer

San Antonio winters are mild, but the attic still gets cold enough on a clear night to turn indoor humidity into water.

Warm, humid air from showers, cooking and breathing rises through ceiling gaps into the attic. On a cold night the underside of the roof deck can be colder than that air's dew point, so the moisture condenses on the sheathing. It soaks into the wood, wets the insulation below and drips onto the ceiling. From inside the house it looks exactly like a roof leak, except it shows up on cold, dry mornings instead of after rain.

It is worst in three situations: soffit intake buried under insulation, bath fans that vent into the attic instead of outdoors, and attics with no balanced exhaust to carry the moist air out. Repeated over several winters, that moisture darkens and weakens the deck from the inside and rusts the nail tips that come through it.

If water appears during a freeze and it has not rained, it could be condensation, a burst attic pipe or the roof itself. Our guide to freeze damage and winter roof leaks shows how to tell the three apart in a few minutes with a flashlight.

Why it matters in summer

Ventilation does not air-condition the attic, but it keeps heat and moisture from building up around everything up there.

From Atrium inspections since 2016 A dark shingle roof in Central Texas routinely reaches about 160°F at the surface on a summer afternoon. That heat soaks through the deck into the attic, where the ductwork and often the air handler sit. A balanced attic keeps the air up there closer to outdoor temperature, so less heat sits against the ducts and the ceiling insulation.

The effect on shingle temperature itself is modest; ventilation's bigger job is moisture control and meeting the ventilation requirements that shingle manufacturers write into their warranties. We will not quote you an energy savings percentage. Cooling load depends far more on ceiling air sealing and attic insulation, and on where the ducts run, than on vents alone.

What we check

Seven things that decide whether the attic is actually ventilating.

Soffit intake

How much net free area the soffit vents actually give, and whether blown insulation has buried them. We look for rafter baffles at each bay, and for soffits that were painted or caulked shut.

Ridge vent cut and product

Whether the slot under the ridge vent was cut wide enough and run long enough, and what net free area the installed product publishes per foot. A ridge vent over an uncut deck moves no air.

Mixed exhaust

Ridge vent plus turbines, box vents or a powered fan on the same attic. The exhausts short-circuit each other and pull air from one another instead of from the soffits.

Exhaust fan terminations

Where the bath, kitchen and dryer ducts actually end. Ducts that stop in the attic, or that are disconnected from their roof cap, put moisture right where ventilation has to remove it.

Attic moisture signs

Frost or water drops on the deck in cold weather, staining, dark or delaminating sheathing, rusty nail tips and damp, matted insulation.

Heat signs

Brittle or heat-darkened wood near the ridge, radiant barrier condition and shingles aging faster than the roof's age would suggest.

HVAC in the attic

Air handlers and ducts in the attic, sweating or poorly sealed ducts, and return leaks that pull attic air into the house.

Common fixes

Most corrections start at the soffits, not the ridge.

  1. 1.Open buried soffit vents, or add soffit intake where the eaves have too little.
  2. 2.Install rafter baffles so insulation can run to full depth without blocking the intake path.
  3. 3.Recut the ridge slot to the product's required width and fit a ridge vent with the right net free area for the attic.
  4. 4.Remove or cap conflicting exhaust, such as old turbines or box vents left beside a ridge vent, and patch the deck.
  5. 5.Reroute bath and kitchen fans through sealed, insulated duct to a roof or gable cap.
  6. 6.Add a solar attic fan only where the calculation calls for one. Homes with enough ridge line do not need one. See are solar attic fans worth it? and ridge vent vs turbine vents.

What it costs

Priced from your attic's measurements, in writing, before any work.

During a roof replacement: Standard ventilation, balanced intake and exhaust sized to code, is included in the replacement price. Enhanced ventilation, such as solar or powered attic fans or added intake beyond the standard design, is quoted separately.

On an existing roof: standalone ventilation correction is priced after we measure the attic and calculate what it needs, because the work ranges from clearing a few soffits to recutting a ridge. You get a written price before any work starts.

Attic ventilation FAQs

Building code sizes it from attic floor area: 1 square foot of net free area for every 300 square feet of attic floor when intake and exhaust are balanced, or 1 for every 150 when they are not. That total is split roughly half intake at the soffits and half exhaust near the ridge. A 1,500 square foot attic at 1:300 needs about 720 square inches in total, about 360 of intake and 360 of exhaust. Our attic ventilation calculator does the math for your attic.

Too much exhaust, yes. Exhaust that outruns the intake does not move more air through the attic. It pulls its makeup air from the easiest opening it can find, which is often the ceiling below, so conditioned air and indoor humidity get drawn into the attic. Extra intake is rarely a problem. The goal is balance, not the largest number of vents.

On most pitched roofs with a usable ridge, a continuous ridge vent is the better exhaust. It has no moving parts and is sized from its published net free area. Turbines make sense where the ridge is short or missing. Either one needs enough soffit intake, and the two should never be used together over the same attic.

Usually condensation. On a cold San Antonio night the roof deck can drop below the dew point of the warm, humid air rising from the house. That moisture condenses on the underside of the sheathing, wets the insulation and drips, which reads as a roof leak from below. The usual causes are blocked soffit intake, bath fans venting into the attic, unsealed ceiling penetrations and no balanced exhaust. If water appears in freezing weather with no rain, also check for a burst attic supply line.

Yes, if the attic below it is a vented attic. The roofing material does not change the attic's job of moving heat and moisture out. Metal roofs use ridge vent products made for their panel profile, and the soffit intake still has to match the exhaust. The exception is an unvented, sealed attic with insulation at the roof deck, which is designed without vents on purpose.

No. A bath fan that ends in the attic blows warm, wet air straight onto the underside of the roof deck, where it condenses in cool weather and can rot sheathing and grow mold. Bath, kitchen and dryer exhaust should run in sealed, insulated duct to a roof or wall cap with a damper. Ventilation cannot carry away moisture that is being pumped into the attic every day.

Not for every home. A solar fan can lower peak attic air temperature, but measured cooling savings are small, and a fan paired with a ridge vent can pull air in through the ridge instead of the soffits. A home with enough ridge line and open soffit intake usually does not need one. Where the ridge is short and the exhaust numbers do not work passively, a fan can be the right call.

Standard ventilation, balanced intake and exhaust sized to code, is included in the replacement price. Enhanced ventilation, such as solar or powered attic fans or added intake beyond the standard design, is quoted separately.

Sometimes a little, but that is not its main job. Ventilation mostly protects the roof deck and insulation from moisture and keeps the attic from holding heat around ducts. Ceiling air sealing and insulation do more for cooling bills. We do not quote savings percentages, because the result depends on your insulation, ductwork and how the house is used.

We measure the attic floor area, work out the net free area it needs, then compare that with the intake and exhaust actually installed. In the attic we look for buried soffit vents, missing baffles, exhaust fans ending in the attic and moisture signs such as staining, dark sheathing and rusty nail tips. You get the numbers and photos in a written report.