Attic ventilation in San Antonio, calculated instead of guessed.
Soffit intake and ridge exhaust sized from your attic's floor area, so the attic stays dry on winter nights and sheds heat in summer.
Balanced attic ventilation means cool air comes in at the soffits and warm, moist air leaves at the ridge, with roughly equal net free area on each side. The amount is sized from the attic floor area, not guessed from how many vents are on the roof. We calculate it on every inspection, even when the attic looks fine, because buried intake and mismatched exhaust are hard to see from the hatch.
Work out your own attic with the ventilation calculatorWhy it matters in winter, not just summer
San Antonio winters are mild, but the attic still gets cold enough on a clear night to turn indoor humidity into water.
Warm, humid air from showers, cooking and breathing rises through ceiling gaps into the attic. On a cold night the underside of the roof deck can be colder than that air's dew point, so the moisture condenses on the sheathing. It soaks into the wood, wets the insulation below and drips onto the ceiling. From inside the house it looks exactly like a roof leak, except it shows up on cold, dry mornings instead of after rain.
It is worst in three situations: soffit intake buried under insulation, bath fans that vent into the attic instead of outdoors, and attics with no balanced exhaust to carry the moist air out. Repeated over several winters, that moisture darkens and weakens the deck from the inside and rusts the nail tips that come through it.
If water appears during a freeze and it has not rained, it could be condensation, a burst attic pipe or the roof itself. Our guide to freeze damage and winter roof leaks shows how to tell the three apart in a few minutes with a flashlight.
Why it matters in summer
Ventilation does not air-condition the attic, but it keeps heat and moisture from building up around everything up there.
From Atrium inspections since 2016 A dark shingle roof in Central Texas routinely reaches about 160°F at the surface on a summer afternoon. That heat soaks through the deck into the attic, where the ductwork and often the air handler sit. A balanced attic keeps the air up there closer to outdoor temperature, so less heat sits against the ducts and the ceiling insulation.
The effect on shingle temperature itself is modest; ventilation's bigger job is moisture control and meeting the ventilation requirements that shingle manufacturers write into their warranties. We will not quote you an energy savings percentage. Cooling load depends far more on ceiling air sealing and attic insulation, and on where the ducts run, than on vents alone.
What we check
Seven things that decide whether the attic is actually ventilating.
How much net free area the soffit vents actually give, and whether blown insulation has buried them. We look for rafter baffles at each bay, and for soffits that were painted or caulked shut.
Whether the slot under the ridge vent was cut wide enough and run long enough, and what net free area the installed product publishes per foot. A ridge vent over an uncut deck moves no air.
Ridge vent plus turbines, box vents or a powered fan on the same attic. The exhausts short-circuit each other and pull air from one another instead of from the soffits.
Where the bath, kitchen and dryer ducts actually end. Ducts that stop in the attic, or that are disconnected from their roof cap, put moisture right where ventilation has to remove it.
Frost or water drops on the deck in cold weather, staining, dark or delaminating sheathing, rusty nail tips and damp, matted insulation.
Brittle or heat-darkened wood near the ridge, radiant barrier condition and shingles aging faster than the roof's age would suggest.
Air handlers and ducts in the attic, sweating or poorly sealed ducts, and return leaks that pull attic air into the house.
Common fixes
Most corrections start at the soffits, not the ridge.
- 1.Open buried soffit vents, or add soffit intake where the eaves have too little.
- 2.Install rafter baffles so insulation can run to full depth without blocking the intake path.
- 3.Recut the ridge slot to the product's required width and fit a ridge vent with the right net free area for the attic.
- 4.Remove or cap conflicting exhaust, such as old turbines or box vents left beside a ridge vent, and patch the deck.
- 5.Reroute bath and kitchen fans through sealed, insulated duct to a roof or gable cap.
- 6.Add a solar attic fan only where the calculation calls for one. Homes with enough ridge line do not need one. See are solar attic fans worth it? and ridge vent vs turbine vents.
What it costs
Priced from your attic's measurements, in writing, before any work.
During a roof replacement: Standard ventilation, balanced intake and exhaust sized to code, is included in the replacement price. Enhanced ventilation, such as solar or powered attic fans or added intake beyond the standard design, is quoted separately.
On an existing roof: standalone ventilation correction is priced after we measure the attic and calculate what it needs, because the work ranges from clearing a few soffits to recutting a ridge. You get a written price before any work starts.
Attic ventilation FAQs
Related reading
Your intake and exhaust requirement in square inches.
ReadThe physics behind intake, exhaust and balance.
ReadAir sealing first, then insulation, so the attic stays dry.
ReadWhich exhaust fits your roof, and why never both.
ReadWhen a fan helps, and when it fights your ridge vent.
ReadWhy ventilation gets corrected during a reroof.
ReadA vent that leaks or broke, rather than an attic that needs redesigning.
ReadPick your inspection time online
Takes about a minute. Free, engineer-led, with a written report either way.